Um eine installierte Pumpe zu reinigen, befolgen Sie das Verfahren zum Abschalten der Pumpe:

Feb 24, 2022|

Um eine installierte Pumpe zu reinigen, befolgen Sie das Verfahren zum Abschalten der Pumpe:

 

1. Remove all water cooling lines and cut off the primary circuit power supply to the pump heater. 2. Release all pump oil. 3. Unscrew the inlet and front pipe connection bolts and remove the pump from the system. 4. Remove the water cooling cap (if applicable). 5. Remove the nozzle assembly in accordance with the method described in the operation manual of the specific pump model. 6. Carefully clean the inside of the pump body with acetone and flush with isopropyl alcohol. The pump is then blown dry with clean, dry, oil-free compressed air. 7. Carefully clean nozzle assembly with acetone. Wipe all surfaces with isopropyl alcohol and blow dry them with clean, dry, oil-free compressed air. 8. Reinstall the nozzle and water cooling cap to the pump body. Make sure the nozzle is properly aligned with the front stage system (if applicable). 9. Check the condition of o-rings. Replace o-rings that show any signs of aging or compression. 10. Connect the pump to the system.

Warnung:
Nicht in der Nähe einer -Hochtemperaturquelle verwenden. Belüften Sie den Arbeitsbereich mit einem Ventilator und verwenden Sie eine Diffusionspumpe in einem großen, gut -belüfteten Raum. Bei Bedarf kann auch ein separates Atemschutzgerät verwendet werden.
Stellen Sie immer sicher, dass Reinigungsvorgänge in einem großen, gut belüfteten Raum- durchgeführt werden. Bitte tragen Sie eine Schutzbrille, Handschuhe und Schutzkleidung.

motocycle parts coating

IKS PVD-Unternehmen, dekorative Beschichtungsmaschine, Werkzeugbeschichtungsmaschine, DLC-Beschichtungsmaschine, optische Beschichtungsmaschine, PVD-Vakuumbeschichtungslinie, das schlüsselfertige Projekt ist verfügbar. Kontaktieren Sie uns jetzt, E-mail:iks.pvd@foxmail.com


Anfrage senden